Qflex fault finding

If you are experiencing issues with your Qflex system in which it is not outputting any sound or there is a crackling noise coming from the units please check to see if the power light on the master unit is flashing. If the light is flashing pay close attention to the number of times it flashes as this will indicate its fault.

For V1.06 or later:
 
FlashesAlarm TypeDescription
1CheckTemperature warning
2CheckLow Frequency Driver Impedance warning
3CheckHigh Frequency Driver Impedance warning
5FaultLow Frequency Driver Impedance out of range
6FaultHigh Frequency Driver Impedance out of range
7FaultLow Frequency Amplifier over-current
8FaultHigh Frequency Amplifier over-current
9FaultMain Power Voltage out of range - possible short circuit o/p devices
10FaultAmplifier pack Over temperature
11FaultPilot Tone missing
For V1.04
FlashesAlarm TypeDescription
1CheckTemperature warning
2FaultLow Frequency Driver Impedance out of range
3FaultHigh Frequency Driver Impedance out of range
5FaultLow Frequency Amplifier over-current
6FaultHigh Frequency Amplifier over-current
7FaultMain Power Voltage out of range - possible short circuit o/p devices
8FaultAmplifier pack Over Temperature
If your unit is experiencing any of these please submit a query here and advise us as to which issue you are experiencing and we will be able to assist further.
 