M300 / M350: How to sync the delay to MIDI clock

Question

How do I sync the delay to MIDI clock ?

Answer

When MIDI clock is received by the unit, the delay will automatically sync to it. With the TIMING knob, you can set the relation between the clock signal received and the delay time.

With the TIMING knob you multiply this tempo. The range of the TIMING knob is 0.5 to 2.

With a Studio Delay algorithm selected you tap quarter notes in tempo 120 BPM using the TAP key. With the TIMING knob in 12 o’clock position you now have a delay time of 500 ms.

If you turn the TIMING knob fully counter clockwise the actual delay time will be: 0.5 times 500 ms =  250 ms If you turn the TIMING knob fully clockwise the tempo will be: 2 times 500 ms = 1000 ms (1 second).