UnitY: 'NO ASSIGN' error on main page after scene recall

Question

When trying to access the UnitY main page after a scene recall, the screen says NO ASSIGN. What has happened and how do I fix this?

Answer

When recalling an old scene memory that was stored before the TC UnitY card was installed, the settings of the MIDI remote will default to no assign as the UnitY card was not present at that time.

You can reassign the TC UnitY card by selecting turning the knob on the screen, next to the 4 MIDI remote buttons , until you see the UnitY main page again. Now store the scene again, so that the Unity card will be properly assigned, next time you recall the scene.